Measuring a venue's sound level with NIOSH's free app, and what to do with the readings
NIOSH publishes a free iOS sound level meter app with a stated accuracy of plus or minus 2 dBA. How it is meant to be used, its limits, and a worked example of combining readings.
If you want to know how loud a room really is, a phone app is the cheapest way to start. NIOSH, the US government’s occupational safety research institute, publishes one whose accuracy it has tested and states. This article summarises what NIOSH says about it and shows how to turn readings into something meaningful. It is general information, not medical advice; for hearing concerns see a doctor or audiologist.
What NIOSH says about the app
According to NIOSH’s page, the Sound Level Meter (SLM) app measures workplace noise to determine whether workers are exposed to hazardous noise. It is free and combines features of professional sound level meters and noise dosimeters. The page states:
- It is accurate within plus or minus 2 dBA.
- It was tested to standards in a reverberant chamber at the NIOSH acoustics laboratory.
- It meets Type 2 requirements of the IEC 61672:3 standard with a calibrated external microphone.
- It reports multiple metrics: averages such as LAeq and TWA, maximum and peak levels, noise dose and projected dose.
- It supports all three weighting networks, A, C and Z, and lets you calibrate either the internal or an external microphone.
- It can report and share data.
- It is available only on iOS. NIOSH explains that iOS devices share a common hardware and software architecture, so the app can be verified on any iOS device, whereas verifying an Android-based app is not currently possible in its laboratory.
What the app was built for
NIOSH describes the app as a tool for testing workplace noise. Using it at a gig is outside that stated purpose. The claim of accuracy refers to the tested conditions; a crowded room with a phone in a pocket is not those conditions.
A sensible way to use the readings
- Choose a weighting. For comparison with the OSHA and NIOSH numbers used in articles on this site, use A-weighting (dBA).
- Measure at the places people actually stand, such as near the stage, mid-room and at the back, rather than one spot.
- Note how long each level lasts. Dose depends on level and time together.
- Compare with a published table. OSHA’s Table G-16 gives permissible daily durations: 90 dBA for 8 hours, 95 for 4, 97 for 3, 100 for 2, 105 for 1 and 110 for 30 minutes (the table is stated for slow response).
A worked example (invented numbers)
OSHA’s table note says that when exposure is made up of periods at different levels, the combined effect should be considered: if the sum of C1/T1 plus C2/T2 and so on exceeds one, the mixed exposure is considered to exceed the limit value, where C is the time spent at a level and T is the permitted time at that level.
Suppose a phone log of a night showed:
| Period | Level (dBA) | Time spent (hours) | Permitted time at that level (hours) | Fraction |
|---|---|---|---|---|
| Support band | 97 | 0.75 | 3 | 0.25 |
| Headliner, main set | 100 | 1 | 2 | 0.50 |
| Headliner, loud finale | 105 | 0.5 | 1 | 0.50 |
| Total | 1.25 |
The sum, 1.25, is above one, so this made-up night would exceed OSHA’s workplace limit for a worker standing in it. This is an illustration of the arithmetic, not a measurement of any venue, and the limit is a workplace one.
What this article does not say
The NIOSH page does not describe using the app at concerts, and it does not say what level is safe for an audience. The OSHA table is a workplace yardstick. The NIOSH page read does not state the highest level a phone’s built-in microphone can measure; concert levels of 100 to 110 dBA may exceed it, so read NIOSH’s Help Guide before relying on such readings. If you measure a venue, say so with the date, the app version, the phone model and where you stood.
Sources
- NIOSH (CDC), Sound Level Meter App: https://www.cdc.gov/niosh/noise/about/app.html (opened 2026-11-02).
- OSHA, 29 CFR 1910.95, Table G-16: https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.95 (opened 2026-11-02).
Sources
- NIOSH (CDC) — Sound Level Meter App — accessed 2026-11-02
- OSHA — 29 CFR 1910.95, Table G-16 (permissible noise exposures) — accessed 2026-11-02