Reading an earplug's Noise Reduction Rating: the subtraction OSHA actually uses
A box that says NRR 33 does not take 33 dB off the room. OSHA's method subtracts 7 first. A table of what four example ratings leave at 100, 105 and 110 dBA.
Earplug packs in the US carry a Noise Reduction Rating, or NRR. It is tempting to subtract it from the sound level of the room. This is general information, not medical advice; for hearing concerns see a doctor or audiologist. OSHA’s own method for estimating protection does something different, and the difference is easy to compute.
What the rating is
OSHA’s Appendix B to its occupational noise standard says the NRR was developed by the US Environmental Protection Agency, that it must be shown on the hearing protector package, and that it is related to a worker’s noise environment to assess whether the protector gives adequate attenuation. OSHA describes the NRR as a simplification of a method developed by NIOSH.
The subtraction for a level read in dBA
When the noise has been measured with a sound level meter set to A-weighting, OSHA’s method is: subtract 7 dB from the NRR, then subtract the remainder from the A-weighted level to get the estimated A-weighted level under the protector. In symbols: estimated level = measured dBA minus (NRR minus 7).
When the measurement is C-weighted, the method subtracts the full NRR from the C-weighted level.
If your meter is set to A-weighting, the 7 dB rule applies; if C-weighting, subtract the full NRR (OSHA Appendix B).
What four example ratings leave behind
The ratings below are examples, not products. The table applies OSHA’s A-weighted method.
| NRR on the pack | Reduction OSHA’s method gives (NRR minus 7) | Room at 100 dBA | Room at 105 dBA | Room at 110 dBA |
|---|---|---|---|---|
| 33 | 26 dB | 74 dBA | 79 dBA | 84 dBA |
| 25 | 18 dB | 82 dBA | 87 dBA | 92 dBA |
| 22 | 15 dB | 85 dBA | 90 dBA | 95 dBA |
| 15 | 8 dB | 92 dBA | 97 dBA | 102 dBA |
Reading the table
- The numbers on the pack can look 7 dB better than the estimate in this method.
- Compare the estimated levels with the benchmarks in the NIDCD’s page: sounds at or above 85 dBA over long or repeated exposure can cause hearing loss, and concerts are listed at 94 to 110 dBA. A lower-rated plug can still leave the level above 85 dBA in a loud room.
- The estimate is of the level under the protector. It does not include how long you stay, which matters because NIDCD says the louder the sound, the shorter the time it takes for damage.
The caveat in OSHA’s own text
OSHA’s appendix says the calculated attenuation values reflect realistic values only to the extent that the protectors are properly fitted and worn. A rating comes from a laboratory test, and the appendix does not promise that the same reduction will happen in an ear that is badly fitted. OSHA’s method is written for a steady exposure over a work shift; the table above uses constant levels only to illustrate.
What this article does not cover
This is OSHA’s workplace estimation method, not a guide to music-specific earplugs. The appendix says nothing about how well speech or music is heard through different plugs. It describes some employees who have had a significant threshold shift, for whom the protector must reduce exposure to a time-weighted average of 85 dB; that rule is about workplace programmes, not concertgoers. Other agencies publish different derating methods that were not read for this article.
Sources
- OSHA, 29 CFR 1910.95 Appendix B: https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.95AppB (opened 2026-11-02).
- NIDCD, Noise-Induced Hearing Loss: https://www.nidcd.nih.gov/health/noise-induced-hearing-loss (opened 2026-11-02).
Sources
- OSHA — 29 CFR 1910.95 Appendix B, Methods for Estimating the Adequacy of Hearing Protector Attenuation — accessed 2026-11-02
- NIDCD — Noise-Induced Hearing Loss — accessed 2026-11-02